Gilbarco 700 Series Dispenser Error Codes

Field reference for fuel system and underground storage tank technicians. 54 entries, taken from the DropTubeBuilder app.

These notes come from DropTubeBuilder

Reference notes from DropTubeBuilder, the offline field tool for fuel system technicians who cut overfill drop tubes, build tank charts and chase dispenser faults. It works with no cell signal, because the sites do not have any.

Get DropTubeBuilder on the App Store
Gilbarco · 700s

E1

Database corrupted

Gilbarco · 700s

E2

Flash corrupted

Gilbarco · 700s

E3

LON configuration error

Gilbarco · 700s

E4

One or more task not started

Gilbarco · 700s

E5

Cold start was forced

Gilbarco · 700s

E6

Redundant data storage error

Gilbarco · 700s

E7

Calibration switch was not engaged when performing a firmware upgrade

Gilbarco · 700s

E8

Database changed, set as default the new values

Gilbarco · 700s

E9

RAM corrupted

Gilbarco · 700s

E10

Hardware configuration error

Gilbarco · 700s

E12

Restore calibration factors from door node

Gilbarco · 700s

11

Two wire communication error

Gilbarco · 700s

20

Pulser connected and product not mapped or pulser disconnected and product is mapped

Gilbarco · 700s

24

Volume unit type not set

Gilbarco · 700s

26

Pump not calibrated

Gilbarco · 700s

27

Two wire ID changed side A

Gilbarco · 700s

28

Two wire ID changed side B

Gilbarco · 700s

29

Valve not open

Gilbarco · 700s

30

Catastrophic error has occurred on the VaporVac

Gilbarco · 700s

33

E-stop button activated or VaporVac failure on one side

Gilbarco · 700s

35

Configuration data error

Gilbarco · 700s

37

Pin code one changed

Gilbarco · 700s

38

Pin code two changed

Gilbarco · 700s

39

Cash/credit option changed

Gilbarco · 700s

41

Side exist option changed

Gilbarco · 700s

42

PPU option changed or valve stuck/timeout

Gilbarco · 700s

44

PPU board pump handle on at power up

Gilbarco · 700s

50

POS communications lost (disconnected)

Gilbarco · 700s

4307

Blends not programmed

Gilbarco · 700s

4311

Blender - low octane product low flow

Gilbarco · 700s

4312

Blender - high octane product low flow

Gilbarco · 700s

4313

Blender - low octane product no flow

Gilbarco · 700s

4314

Blender - high octane product no flow

Gilbarco · 700s

4320

Valve configured for, but not responding

Gilbarco · 700s

4321

Valve stuck

Gilbarco · 700s

4322

Valve board not responding

Gilbarco · 700s

5000

Meter 0 calibration changed

Gilbarco · 700s

5001

Meter 1 calibration changed

Gilbarco · 700s

5002

Meter 2 calibration changed

Gilbarco · 700s

5003

Meter 3 calibration changed

Gilbarco · 700s

5041

Power fail - power circuit register a power loss

Gilbarco · 700s

5047

Reverse flow detect

Gilbarco · 700s

5048

No flow detect

Gilbarco · 700s

5049

Unauthorized flow detected

Gilbarco · 700s

5050

Invalid pulser - pulser pattern does not fit profiled meter

Gilbarco · 700s

5094

Main board communication lost

Gilbarco · 700s

5095

Main board power failure

Gilbarco · 700s

5096

Board temperature too high

Gilbarco · 700s

5150

PPUs not addressed correctly

Gilbarco · 700s

5151

PPUs communication lost

Gilbarco · 700s

5152

PPU configuration mismatch

Gilbarco · 700s

5153

PPU reset failed

Gilbarco · 700s

5200

Display initialization failure

Gilbarco · 700s

5201

Display data corruption detected

These notes come from DropTubeBuilder

Reference notes from DropTubeBuilder, the offline field tool for fuel system technicians who cut overfill drop tubes, build tank charts and chase dispenser faults. It works with no cell signal, because the sites do not have any.

Get DropTubeBuilder on the App Store

These notes are a field aid, not a substitute for the governing codes, the stamped drawings, the authority having jurisdiction, or manufacturer manuals. Verify against the current documentation for your installed equipment.