Gilbarco 500 Series Dispenser Error Codes

Field reference for fuel system and underground storage tank technicians. 151 entries, taken from the DropTubeBuilder app.

These notes come from DropTubeBuilder

Reference notes from DropTubeBuilder, the offline field tool for fuel system technicians who cut overfill drop tubes, build tank charts and chase dispenser faults. It works with no cell signal, because the sites do not have any.

Get DropTubeBuilder on the App Store
Gilbarco · 500s

E1

Database corrupted

Gilbarco · 500s

E2

Flash corrupted

Gilbarco · 500s

E3

LON configuration error

Gilbarco · 500s

E4

One or more task not started

Gilbarco · 500s

E5

Cold start was forced

Gilbarco · 500s

E6

Redundant data storage error

Gilbarco · 500s

E7

Calibration switch was not engaged when performing a firmware upgrade

Gilbarco · 500s

E8

Database changed, set as default the new values

Gilbarco · 500s

E9

RAM corrupted

Gilbarco · 500s

E10

Hardware configuration error

Gilbarco · 500s

E12

Restore calibration factors from door node

Gilbarco · 500s

11

Two wire communication error

Gilbarco · 500s

20

Pulser connected and product not mapped or pulser disconnected and product is mapped

Gilbarco · 500s

24

Volume unit type not set

Gilbarco · 500s

26

Pump not calibrated

Gilbarco · 500s

27

Two wire ID changed side A

Gilbarco · 500s

28

Two wire ID changed side B

Gilbarco · 500s

29

Valve not open

Gilbarco · 500s

30

Catastrophic error has occurred on the VaporVac

Gilbarco · 500s

33

E-stop button activated or VaporVac failure on one side

Gilbarco · 500s

35

Configuration data error

Gilbarco · 500s

37

Pin code one changed

Gilbarco · 500s

38

Pin code two changed

Gilbarco · 500s

39

Cash/credit option changed

Gilbarco · 500s

41

Side exist option changed

Gilbarco · 500s

42

PPU option changed or valve stuck/timeout

Gilbarco · 500s

44

PPU board pump handle on at power up

Gilbarco · 500s

50

POS communications lost (disconnected)

Gilbarco · 500s

4307

Blends not programmed

Gilbarco · 500s

4311

Blender - low octane product low flow

Gilbarco · 500s

4312

Blender - high octane product low flow

Gilbarco · 500s

4313

Blender - low octane product no flow

Gilbarco · 500s

4314

Blender - high octane product no flow

Gilbarco · 500s

4315

Blender - high octane product contaminated by low octane product

Gilbarco · 500s

4316

Blender - low octane product contaminated by high octane product

Gilbarco · 500s

4320

Valve configured for, but not responding

Gilbarco · 500s

4321

Valve stuck

Gilbarco · 500s

4322

Valve board not responding

Gilbarco · 500s

5000

Meter 0 calibration changed

Gilbarco · 500s

5001

Meter 1 calibration changed

Gilbarco · 500s

5002

Meter 2 calibration changed

Gilbarco · 500s

5003

Meter 3 calibration changed

Gilbarco · 500s

5004

Meter 4 calibration changed

Gilbarco · 500s

5005

Meter 5 calibration changed

Gilbarco · 500s

5006

Meter 6 calibration changed

Gilbarco · 500s

5007

Meter 7 calibration changed

Gilbarco · 500s

5037

Display button pressed during power up

Gilbarco · 500s

5041

Power fail - power circuit register a power loss

Gilbarco · 500s

5047

Reverse flow detect

Gilbarco · 500s

5048

No flow detect

Gilbarco · 500s

5049

Unauthorized flow detected

Gilbarco · 500s

5050

Invalid pulser - pulser pattern does not fit profiled meter

Gilbarco · 500s

5066

STP 1 configured for, but not connected

Gilbarco · 500s

5067

STP 2 configured for, but not connected

Gilbarco · 500s

5094

Main board communication lost

Gilbarco · 500s

5095

Main board power failure

Gilbarco · 500s

5139

Button configuration error

Gilbarco · 500s

5150

PPUs not addressed correctly

Gilbarco · 500s

5151

PPUs communication lost

Gilbarco · 500s

5152

PPU configuration mismatch

Gilbarco · 500s

5153

PPU reset failed

Gilbarco · 500s

5200

Display initialization failure

Gilbarco · 500s

5201

Display data corruption detected

Gilbarco · 500s

5600

Density measurement out of range

Gilbarco · 500s

5601

Temperature measurement out of range

Gilbarco · 500s

5617

Security switch tamper detected

Gilbarco · 500s

5801

CNG pressure sensor failure

Gilbarco · 500s

5815

CNG temperature sensor failure

Gilbarco · 500s

6002

Vapor recovery system failure

Gilbarco · 500s

6361

Grade selection error

Gilbarco · 500s

8022

Encrypted pulser tamper detection

Gilbarco · 500s

8050

Hardware fault detected

Gilbarco · 500s

5008

Blend ratio changed for product 1

Gilbarco · 500s

5009

Blend ratio changed for product 2

Gilbarco · 500s

5010

Blend ratio changed for product 3

Gilbarco · 500s

5011

Blend ratio changed for product 4

Gilbarco · 500s

5012

Blend ratio changed for product 5

Gilbarco · 500s

5013

Blend ratio changed for product 6

Gilbarco · 500s

5014

Blend ratio changed for product 7

Gilbarco · 500s

5015

Blend ratio changed for product 8

Gilbarco · 500s

5016

Flow control setting changed per product 1

Gilbarco · 500s

5017

Flow control setting changed per product 2

Gilbarco · 500s

5018

Flow control setting changed per product 3

Gilbarco · 500s

5019

Flow control setting changed per product 4

Gilbarco · 500s

5020

Flow control setting changed per product 5

Gilbarco · 500s

5021

Flow control setting changed per product 6

Gilbarco · 500s

5022

Flow control setting changed per product 7

Gilbarco · 500s

5023

Flow control setting changed per product 8

Gilbarco · 500s

5024

ATC enabled

Gilbarco · 500s

5025

ATC disabled

Gilbarco · 500s

5026

ATC base value changed

Gilbarco · 500s

5027

Sealable switches have been accessed

Gilbarco · 500s

5028

Measurement unit volume changed to liters

Gilbarco · 500s

5029

Measurement unit volume changed to gallons

Gilbarco · 500s

5030

Measurement unit volume changed to imperial gallons

Gilbarco · 500s

5031

Measurement unit volume changed to Hawaiian gallons

Gilbarco · 500s

5068

STP 3 configured for, but not connected

Gilbarco · 500s

5069

STP 4 configured for, but not connected

Gilbarco · 500s

5070

Vapor vacuum option set, but VV board not present

Gilbarco · 500s

5071

Vapor vacuum option not set, but VV board is present

Gilbarco · 500s

5072

Vapor vacuum option set connected

Gilbarco · 500s

5074

Vapor vacuum motor not responding

Gilbarco · 500s

5079

Valve not configured for, but is responding

Gilbarco · 500s

5081

Air sensor NOT connected, but option is set

Gilbarco · 500s

5091

ATC node communication failure, ATC option set

Gilbarco · 500s

5092

ATC node present, but not configured for

Gilbarco · 500s

5098

T-meter not connected

Gilbarco · 500s

5099

ATC-number of probes exceed number of meters

Gilbarco · 500s

5100

ATC-number of meters exceeds number of probes

Gilbarco · 500s

5101

No pulse train detected from T-meters. The t-meter is connected

Gilbarco · 500s

5111

Door node communication failure

Gilbarco · 500s

5115

Door node software download flash error

Gilbarco · 500s

5116

Door node software download incomplete

Gilbarco · 500s

5118

PPU board communication failure

Gilbarco · 500s

5119

PPU board present, but not configured for

Gilbarco · 500s

5120

PPU board pump handle not connected

Gilbarco · 500s

5121

PPU board grade select button not connected

Gilbarco · 500s

5126

Key stuck on manager keypad

Gilbarco · 500s

5131

PPP keypad option set, but not present

Gilbarco · 500s

5132

PPP keypad present, but not configured for

Gilbarco · 500s

5133

Key stuck on PPP keypad

Gilbarco · 500s

5134

Call button option set, but not present

Gilbarco · 500s

5135

Call button present, not configured for

Gilbarco · 500s

5136

Call button stuck

Gilbarco · 500s

5137

E-stop option set, but not present

Gilbarco · 500s

5138

E-stop button present, but not configured for

Gilbarco · 500s

5140

Push to start button option set, but not present

Gilbarco · 500s

5141

Push to start button present, but not configured for

Gilbarco · 500s

5142

Push to start button stuck

Gilbarco · 500s

5171

Power fail manager keypad mode exited

Gilbarco · 500s

5174

Totalizer node communication failure

Gilbarco · 500s

5175

Totalizer node detected, but not configured for

Gilbarco · 500s

5183

Totalizer present, but no return pulse detected

Gilbarco · 500s

5198

Measurement unit changed not programmed

Gilbarco · 500s

5199

Measurement unit changed 500 pulses per gallon

Gilbarco · 500s

5235

Database corrupted

Gilbarco · 500s

5236

Database build process started

Gilbarco · 500s

5239

Database unit forced

Gilbarco · 500s

5240

Database wrong read or read failed

Gilbarco · 500s

5241

Database write failed

Gilbarco · 500s

5378

Customer interface door node configuration not received

Gilbarco · 500s

5413

PPU option pump handle not connected correctly

Gilbarco · 500s

5602

ATC node incorrect software version

Gilbarco · 500s

5603

Door node incorrect software version

Gilbarco · 500s

5604

Totalizer node incorrect software version

Gilbarco · 500s

5605

MIP node incorrect software version

Gilbarco · 500s

5606

ATC node subscription failed

Gilbarco · 500s

5607

Door node subscription failed

Gilbarco · 500s

5608

Totalizer node subscription failed

Gilbarco · 500s

5612

TW converter error

Gilbarco · 500s

5613

Pump updated with data from door node storage

These notes come from DropTubeBuilder

Reference notes from DropTubeBuilder, the offline field tool for fuel system technicians who cut overfill drop tubes, build tank charts and chase dispenser faults. It works with no cell signal, because the sites do not have any.

Get DropTubeBuilder on the App Store

These notes are a field aid, not a substitute for the governing codes, the stamped drawings, the authority having jurisdiction, or manufacturer manuals. Verify against the current documentation for your installed equipment.