Field reference for fuel system and underground storage tank technicians. 151 entries, taken from the DropTubeBuilder app.
Reference notes from DropTubeBuilder, the offline field tool for fuel system technicians who cut overfill drop tubes, build tank charts and chase dispenser faults. It works with no cell signal, because the sites do not have any.
Get DropTubeBuilder on the App StoreDatabase corrupted
Flash corrupted
LON configuration error
One or more task not started
Cold start was forced
Redundant data storage error
Calibration switch was not engaged when performing a firmware upgrade
Database changed, set as default the new values
RAM corrupted
Hardware configuration error
Restore calibration factors from door node
Two wire communication error
Pulser connected and product not mapped or pulser disconnected and product is mapped
Volume unit type not set
Pump not calibrated
Two wire ID changed side A
Two wire ID changed side B
Valve not open
Catastrophic error has occurred on the VaporVac
E-stop button activated or VaporVac failure on one side
Configuration data error
Pin code one changed
Pin code two changed
Cash/credit option changed
Side exist option changed
PPU option changed or valve stuck/timeout
PPU board pump handle on at power up
POS communications lost (disconnected)
Blends not programmed
Blender - low octane product low flow
Blender - high octane product low flow
Blender - low octane product no flow
Blender - high octane product no flow
Blender - high octane product contaminated by low octane product
Blender - low octane product contaminated by high octane product
Valve configured for, but not responding
Valve stuck
Valve board not responding
Meter 0 calibration changed
Meter 1 calibration changed
Meter 2 calibration changed
Meter 3 calibration changed
Meter 4 calibration changed
Meter 5 calibration changed
Meter 6 calibration changed
Meter 7 calibration changed
Display button pressed during power up
Power fail - power circuit register a power loss
Reverse flow detect
No flow detect
Unauthorized flow detected
Invalid pulser - pulser pattern does not fit profiled meter
STP 1 configured for, but not connected
STP 2 configured for, but not connected
Main board communication lost
Main board power failure
Button configuration error
PPUs not addressed correctly
PPUs communication lost
PPU configuration mismatch
PPU reset failed
Display initialization failure
Display data corruption detected
Density measurement out of range
Temperature measurement out of range
Security switch tamper detected
CNG pressure sensor failure
CNG temperature sensor failure
Vapor recovery system failure
Grade selection error
Encrypted pulser tamper detection
Hardware fault detected
Blend ratio changed for product 1
Blend ratio changed for product 2
Blend ratio changed for product 3
Blend ratio changed for product 4
Blend ratio changed for product 5
Blend ratio changed for product 6
Blend ratio changed for product 7
Blend ratio changed for product 8
Flow control setting changed per product 1
Flow control setting changed per product 2
Flow control setting changed per product 3
Flow control setting changed per product 4
Flow control setting changed per product 5
Flow control setting changed per product 6
Flow control setting changed per product 7
Flow control setting changed per product 8
ATC enabled
ATC disabled
ATC base value changed
Sealable switches have been accessed
Measurement unit volume changed to liters
Measurement unit volume changed to gallons
Measurement unit volume changed to imperial gallons
Measurement unit volume changed to Hawaiian gallons
STP 3 configured for, but not connected
STP 4 configured for, but not connected
Vapor vacuum option set, but VV board not present
Vapor vacuum option not set, but VV board is present
Vapor vacuum option set connected
Vapor vacuum motor not responding
Valve not configured for, but is responding
Air sensor NOT connected, but option is set
ATC node communication failure, ATC option set
ATC node present, but not configured for
T-meter not connected
ATC-number of probes exceed number of meters
ATC-number of meters exceeds number of probes
No pulse train detected from T-meters. The t-meter is connected
Door node communication failure
Door node software download flash error
Door node software download incomplete
PPU board communication failure
PPU board present, but not configured for
PPU board pump handle not connected
PPU board grade select button not connected
Key stuck on manager keypad
PPP keypad option set, but not present
PPP keypad present, but not configured for
Key stuck on PPP keypad
Call button option set, but not present
Call button present, not configured for
Call button stuck
E-stop option set, but not present
E-stop button present, but not configured for
Push to start button option set, but not present
Push to start button present, but not configured for
Push to start button stuck
Power fail manager keypad mode exited
Totalizer node communication failure
Totalizer node detected, but not configured for
Totalizer present, but no return pulse detected
Measurement unit changed not programmed
Measurement unit changed 500 pulses per gallon
Database corrupted
Database build process started
Database unit forced
Database wrong read or read failed
Database write failed
Customer interface door node configuration not received
PPU option pump handle not connected correctly
ATC node incorrect software version
Door node incorrect software version
Totalizer node incorrect software version
MIP node incorrect software version
ATC node subscription failed
Door node subscription failed
Totalizer node subscription failed
TW converter error
Pump updated with data from door node storage
Reference notes from DropTubeBuilder, the offline field tool for fuel system technicians who cut overfill drop tubes, build tank charts and chase dispenser faults. It works with no cell signal, because the sites do not have any.
Get DropTubeBuilder on the App StoreThese notes are a field aid, not a substitute for the governing codes, the stamped drawings, the authority having jurisdiction, or manufacturer manuals. Verify against the current documentation for your installed equipment.